Gas pipeline leak, pressure detector model: BMT8GasTest delta
BMT8GasTest delta is currently the best instrument for detecting combustible gas leakage and confirming the leakage point of pipelines. Hand-held semiconductor sensor probe can be used to detect extremely small amounts of gas concentration, and can sound and light alarm.
Product use Tracer gas to detect leakage points of gas, heat and water pipelines. Can choose to detect natural gas or tracer gas (hydrogen and nitrogen mixed gas). For newly-built pipelines, the extremely small leak points of gas, water, and thermal pipelines can be detected with a handheld, bell-shaped hydrogen sensor probe through a hydrogen-nitrogen mixed tracer gas. It should be noted that the tracer gas is injected into the pipeline before detection, and the hydrogen overflows from the leak point and penetrates vertically to the ground. On the ground, the instrument can detect the tracer gas with a concentration of less than 5ppm.
Features
Menu-guided function, easy to measure the leakage amount of leakage point. Pressure regulator and shutdown safety valve with infrared interface and RS232 transmission interface, can provide accurate measurement. Rugged aluminum instrument box, large screen can display all detection parameters. Collect and print data on site, provide printout graphics, internal data storage can save the measurement results or transfer to the computer to record more detailed measurement data.
Pressure measurement Two 10-minute pressure test ranges: 0 ~ 0.2 kg / cm² and 0 ~ 2 kg / cm²
Display the initial pressure, current pressure, final pressure and pressure change leakage detection to detect the leakage of gas transmission and distribution facilities under working pressure.
From the data storage, the leakage, pressure and detection time are displayed.
Pressure calibration test During the pressure test, self-check the working condition of the pressure switch and safety valve. Select the desired measurement mode according to the menu. The screen displays the current pressure value. If the test value is reached, the safety valve is activated and the measured value can be saved by pressing the save button.
Tracer gas leak detection can obtain all saved measurement data from the menu. Measurement data can be printed or deleted.
The hydrogen concentration curve can be drawn in the range of 0 – 10.000 ppm.
Gas pipeline concentration range methane 0 – 10.000 ppm Alarm value can be set to 1, 10, 50, 100, 1000 ppm
The data storage memory is 500 kbyte (kilobytes), which stores more than 300 measurement data.
Pressure measurement range 0 ~ 200mbar / 0 ~ 2000mbar / 0 ~ 10 l / h, corresponding accuracy 0.1mbar / 1mbar / 0.01 l / h
Battery: 230V AC / 12V DC, rechargeable NIMH battery pack without memory
Working hours:> 20 hours
Weight: 0.85 kg (including battery)
Dimensions: 180 x 95 x 60 mm
Working temperature: 00C ~ 400C
Standard configuration: host, charger, printer, sampling valve, hand-held probe, bell probe
NANTONG OUFEIYA IMP& EXP CO.,LTD , https://www.nantongoufeiya.com